Previous slide
Next slide
Toggle fullscreen
Toggle overview view
Open presenter view
Data Storage Hierarchies and RAID Levels
Disks, Buffers, and RAID Mechanics
Writer:
0x03ff
2026-11-12
Memory Layers
Nonvolatile Memory:
Retains data without power (SSD, HDD, Flash).
Volatile Memory:
Requires power to retain data (RAM, Cache).
Storage Type
Example
Feature
Speed
Cost
Primary
Main Memory (RAM), Cache
Fast, volatile, direct CPU access
Extremely Fast
High
Secondary
Magnetic Disk, SSD
Non-volatile, block-level access
Moderate
Medium
Tertiary
Magnetic Tape, Optical Disks
Mass archival storage, offline/nearline
Slow
Low
Disk Architecture
Direct access capability
Disk blocks / pages
Tracks, Platters, Cylinders, Sectors
Disk head and arm assembly
Single process execution (raw case includes dual parallel disk heads)
Disk controller and checksum mechanisms
Access performance metrics: Seek time, Rotational delay, Transfer time
Disk Structure & Access Mechanics
Data Loading:
Data is loaded from disk into main memory.
I/O Unit:
Disk and main memory use the block (or page) as the basic data transmission unit for read/write operations.
Access Time Components:
Access Time = Seek Time + Rotational Delay + Transfer Time
Locality Principle:
Frequently accessed data is placed close together (same sector > same cylinder > adjacent cylinders). Sequential reading of the same block allows access to all data in a single movement.
Redundant Disk Arrays (RAID)
Disk array architecture
Data striping across multiple disks
Reliability and fault tolerance
Data Segmentation & Striping
User I/O Request:
User issues a read/write request.
Block Identification:
Identify data with physical disk block groups.
Block Retrieval:
Fetch blocks from disk across different drives.
Striping Unit (
i
mod
D
):
Distributes data blocks across
D
disks.
Total Bandwidth:
Parallel reading of
D
blocks across
D
disks maximizes total disk bandwidth.
Parallelism:
Concurrent multi-size I/O requests process in parallel to reduce average response time.
Redundancy and RAID Levels
Key Metrics:
Mean Time To Failure (MTTF), Mean Time Between Failures (MTBF), Parity, Hamming Code (ECC), CRC, Reed-Solomon.
Reliability Note:
A high MTTF indicates a low failure rate, though real-world operational lifecycles are typically far shorter (standard disk replacement cycle of ~10 years).
RAID Capacity Scaling Rules (
N
N
N
Disks)
RAID 0 & 1 (Fixed Ratio):
RAID 0:
100
%
100\%
100%
usable space (all
N
N
N
disks store data).
RAID 1 / 01 / 10:
50
%
50\%
50%
usable space (half of the disks are mirrors).
RAID 2 (Hamming Code Scaling):
Varies non-linearly:
2
C
≥
D
+
C
+
1
2^C \ge D + C + 1
2
C
≥
D
+
C
+
1
(
D
D
D
data disks,
C
C
C
ECC disks).
RAID 3, 4 & 5 (Single Parity Rule):
Varies with
(
N
−
1
)
/
N
(N - 1) / N
(
N
−
1
)
/
N
(1 disk equivalent used for parity; efficiency rises with more disks).
RAID 6 (Dual Parity Rule):
Varies with
(
N
−
2
)
/
N
(N - 2) / N
(
N
−
2
)
/
N
(2 disks equivalent used for
P
+
Q
P+Q
P
+
Q
parity).
RAID (0, 1): Speed vs. Safety
Level
Meaning
Details / N-disk Setup
Space Usage
Recovery Capability
RAID 0
Non-redundant (Striping)
Full bandwidth utilization, uses all disks for storage, no parity/redundancy
100%
None (disk failure causes data loss)
RAID 1
Mirroring
Maintains two identical copies across disks; writes to primary then mirror; parallel reads
50%
Tolerates failure of 1 disk per mirrored pair
RAID (01, 10): Structure & Resilience
Level
Meaning
Details / N-disk Setup
Space Usage
Recovery Capability
RAID 01
Stripe of Mirrors
Striping over mirrored arrays; higher error vulnerability than RAID 10
50%
Lower fault tolerance than RAID 10
RAID 10
Mirror of Stripes
Combines striping and mirroring for high performance and reliability
50%
Tolerates multiple disk failures (if in different pairs)
RAID (2, 3): Early Parity Evolution
Level
Meaning
Details / N-disk Setup
Space Usage
Recovery Capability
RAID 2
Hamming Code
Smallest transfer unit is
D
data +
C
ECC blocks; optimized for large requests
Varies
10-disk: 60%
Recovers single/multiple bit errors via Hamming code
RAID 3
Parity (Byte-level)
Uses a dedicated disk controller and a dedicated parity disk for failure identification
Varies:
(
N
−
1
)
/
N
(N-1)/N
(
N
−
1
)
/
N
10-disk: 90%
Recovers single disk failure
RAID (4, 5): Parity Optimization
Level
Meaning
Details / N-disk Setup
Space Usage
Recovery Capability
RAID 4
Parity (Block-level)
Block-level unit; independent reads per disk, full bandwidth on large I/O; dedicated XOR parity disk
Varies:
(
N
−
1
)
/
N
(N-1)/N
(
N
−
1
)
/
N
10-disk: 90%
Recovers single disk failure
RAID 5
Parity (Distributed)
Distributed parity across all disks; removes single-disk bottleneck; great for reads, slow for small random writes
Varies:
(
N
−
1
)
/
N
(N-1)/N
(
N
−
1
)
/
N
10-disk: 90%
Recovers single disk failure
RAID (6): Ultimate Protection
Level
Meaning
Details / N-disk Setup
Space Usage
Recovery Capability
RAID 6
P+Q Redundancy
Dual parity using Reed-Solomon codes; protects against double disk failures; similar read profile to RAID 5
Varies:
(
N
−
2
)
/
N
(N-2)/N
(
N
−
2
)
/
N
10-disk: 80%
Recovers simultaneous failure of up to 2 disks
Choosing a RAID Level
Cost/performance priority
(if data loss is acceptable):
RAID 0 > RAID 10 > RAID 1
Write performance priority:
RAID 10 > RAID 1
Parity evolution:
RAID 2 → RAID 3 → RAID 5
Maximum redundancy required:
RAID 6